Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.242
Filtrar
1.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656029

RESUMO

PURPOSE: To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages. METHODS: Forty-five patients (45 eyes) with keratoconus scar stage (scar group, n=26; penetrating keratoplasty a subgroup, n=7; deep anterior lamellar keratoplasty b subgroup, n=19) and keratoconus edema stage (edema group, n=19; penetrating keratoplasty c subgroup, n=12; deep anterior lamellar keratoplasty d group, n=7) who received penetrating keratoplasty or deep anterior lamellar keratoplasty from 2000 to 2022 were retrospectively studied. At 1, 6, and 12 months after surgery, the best-corrected visual acuity, astigmatism, spherical equivalent, corneal endothelial cell density, and complications were analyzed. RESULTS: The best-corrected visual acuity and average corneal endothelial cell loss rate were not significantly different between the scar and edema groups (p>0.05). At 6 and 12 months after surgery, the astigmatism and spherical equivalent in the scar group were significantly lower than those in the edema group (p<0.05). The spherical equivalent of the deep anterior lamellar keratoplasty b subgroup was lower than that of the penetrating keratoplasty a subgroup in the scar group 6 months after surgery (p<0.05). In the edema group, there was no significant difference in spherical equivalent between subgroups (p>0.05). There were no significant differences in best-corrected visual acuity and astigmatism between subgroups within the two groups (p>0.05). In comparison to the scar group, the edema group experienced more complications. According to a survival analysis, there was no statistically significant difference between the scar group and the edema group regarding the progression of vision. CONCLUSIONS: In terms of the outcomes and prognosis for vision after keratoplasty with edema stage and scar stage, deep anterior lamellar keratoplasty may be as effective as penetrating keratoplasty.


Assuntos
Cicatriz , Edema da Córnea , Ceratocone , Ceratoplastia Penetrante , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/complicações , Ceratocone/fisiopatologia , Masculino , Feminino , Estudos Retrospectivos , Ceratoplastia Penetrante/métodos , Adulto , Cicatriz/etiologia , Resultado do Tratamento , Edema da Córnea/cirurgia , Edema da Córnea/etiologia , Adulto Jovem , Transplante de Córnea/métodos , Fatores de Tempo , Adolescente , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Contagem de Células , Endotélio Corneano/patologia , Endotélio Corneano/cirurgia
2.
J Cataract Refract Surg ; 50(5): 523-533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288954

RESUMO

Corneal crosslinking (CXL) is used for treating keratoconus and post-laser in situ keratomileusis ectasia. However, refractive surgery is not usually performed with prophylactic CXL. Therefore, we performed a meta-analysis comparing outcomes of refractive surgeries with vs without prophylactic CXL. We systematically searched databases for studies comparing refractive surgeries for myopic correction with vs without prophylactic corneal crosslinking. Review Manager 5.4.1 was used to perform statistical analysis. We included 2820 eyes from 28 studies. Compared with refractive surgery alone, surgery with prophylactic CXL resulted in decreased central corneal thickness, corrected distance visual acuity logMAR, and safety and efficacy indices. There were no significant differences in postoperative uncorrected distance visual acuity of 20/20 or better at ≥12 months and other visual outcomes among both groups. More randomized controlled trials with standard crosslinking protocols are needed to analyze the prophylactic use of crosslinking with refractive surgeries.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Fármacos Fotossensibilizantes , Riboflavina , Acuidade Visual , Humanos , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Riboflavina/uso terapêutico , Colágeno/metabolismo , Acuidade Visual/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Fotoquimioterapia/métodos , Lasers de Excimer/uso terapêutico , Substância Própria/metabolismo , Substância Própria/cirurgia , Raios Ultravioleta , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia
3.
Cont Lens Anterior Eye ; 46(2): 101794, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36513565

RESUMO

PURPOSE: To determine 1) the relative differences in optical quality of keratoconic eyes fitted with four routinely used CL designs and 2) the Zernike coefficients in the residual wavefront aberration map that may be responsible for differences in the optical quality of keratoconic eyes fitted with these CLs. METHODS: Wavefront aberrations over a 3-mm pupil diameter were measured without and with Kerasoft IC®, Rose K2®, conventional spherical Rigid Gas Permeable (RGP), and Scleral CLs in 15 mild to moderate keratoconic eyes (20 - 28 years) and under unaided viewing in 10 age-similar non-contact lens wearing controls. The resultant through-focus curves constructed for the logarithm of Neural Sharpness (logNS) Image Quality (IQ) metric were quantified in terms of peak value, best focus, and depth of focus. Sensitivity analyses determined the impact of the residual Zernike coefficients of keratoconic eyes fitted with CLs on the IQ of controls at emmetropic refraction. RESULTS: The peak IQ and depth of focus were similar with Rose K2®, conventional RGP, and Scleral CLs (p > 0.05, for all) but significantly better than Kerasoft IC® CLs (p < 0.01 for all). Best focus was similar across all four CLs (p > 0.2 for all). However, the IQ parameters of all the lenses remained significantly poorer than the controls (p < 0.01, for all). The IQ of the controls dropped to keratoconic levels with induced residual lower-order Zernike terms and 3rd-order coma across all lenses in the sensitivity analysis (p < 0.001). CONCLUSIONS: IQ of keratoconic eyes remain suboptimal with routinely dispensed CL designs, largely due to residual lower-order aberrations and coma, all relative to the controls. The performance drop appears greater for the Kerasoft IC® CL relative to the other CL designs. These results may provide the optical basis for psychophysical spatial visual performance reported earlier across these four CL designs for keratoconus.


Assuntos
Lentes de Contato , Processamento de Imagem Assistida por Computador , Ceratocone , Retina , Adulto , Humanos , Adulto Jovem , Estudos de Casos e Controles , Desenho de Equipamento , Ceratocone/diagnóstico por imagem , Ceratocone/fisiopatologia , Ceratocone/terapia , Retina/diagnóstico por imagem , Retina/fisiologia , Resultado do Tratamento
4.
Cornea ; 41(4): 456-461, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244626

RESUMO

PURPOSE: The purpose of this study was to assess an intellectual disability (ID) cohort with keratoconus (KC) regarding ophthalmic (visual acuity and corneal tomography) and systemic characteristics and to describe an appropriate clinical algorithm for investigation and management of KC in this setting. METHODS: This was the retrospective cohort study of patients with ID (Down syndrome, autism, and other) in the cornea department of a tertiary referral ophthalmic hospital in Dublin, Ireland. Retrospective chart review was conducted on people with ID undergoing examination under anesthesia or crosslinking under general anesthetic. Key outcome data included corneal examination findings, corneal tomography, visual acuity, and examination findings (eg, type of ID, general anesthetic, and cardiac status). RESULTS: Mean age of the 24 patients was 31.9 years (66.7% male). ID type was Down syndrome (66.7%), autism (25%), and other (8.3%). KC was diagnosed in 98% of eyes, with 45.8% having untreatable advanced disease (57.1% of these bilateral), 39.6% amenable to corneal collagen crosslinking (35.7% of these bilateral), and 6.3% having corneal transplantation. Congenital heart defects were present in 37.5% of the Down syndrome group. There were no serious ocular or systemic adverse events. CONCLUSIONS: KC is strikingly prevalent in the ID population. Ireland has the highest rate of Down syndrome in Europe (26.3:10,000 live births). This group is rarely suitable for corneal transplantation, and corneal collagen crosslinking is an effective intervention to prevent progression to advanced KC in this already socially restricted group. We propose an algorithm for investigation/treatment and also recommend uniform pediatric KC screening/treatment in ID populations.


Assuntos
Transtorno do Espectro Autista/complicações , Transplante de Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Síndrome de Down/complicações , Deficiência Intelectual/complicações , Ceratocone/terapia , Adolescente , Adulto , Criança , Colágeno/metabolismo , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Seguimentos , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/fisiopatologia , Ceratocone/cirurgia , Masculino , Pessoa de Meia-Idade , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
5.
Cornea ; 41(4): 450-455, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244625

RESUMO

PURPOSE: The purpose of this study was to investigate 3-year changes in keratoconus (KC) indices to determine the indicators of KC progression compared with age-related changes in children aged 6 to 12 years. METHODS: In this report of the Shahroud Schoolchildren Eye Cohort Study, KC was diagnosed based on vision, refraction, tomography, and slitlamp examination findings. KC progression was defined as changes in refractive astigmatism or zonal maximum keratometry (Zonal Kmax-3 mm). Then, 3-year changes (Δ) in vision, refraction, and tomographic indices were compared between progressive KC and normal eyes. The best set of ∆parameters for distinguishing KC progression from age-related changes were determined using the area under curve (AUC). RESULTS: Eighteen KC eyes and 10,422 normal eyes were analyzed. All KC cases showed progression after 3 years. Δindices were statistically different between the 2 groups except corrected distance visual acuity, anterior radius of curvature, irregularity index, and KC percentage index. The best Δindices, in descending order of AUC value, were index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry (all AUC > 0.9), followed by inferior-superior asymmetry, index of surface variance, minimum corneal thickness, index of height asymmetry, KC index, posterior radius of curvature, and Belin/Ambrósio total Deviation (AUC = 0.8-0.9). CONCLUSIONS: According to our findings, changes in index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry are the best indices for detecting KC progression in children younger than 12 years.


Assuntos
Ceratocone/diagnóstico , Envelhecimento/fisiologia , Fenômenos Biomecânicos , Criança , Córnea/fisiopatologia , Paquimetria Corneana , Topografia da Córnea , Progressão da Doença , Feminino , Humanos , Ceratocone/epidemiologia , Ceratocone/fisiopatologia , Masculino , Prevalência , Curva ROC , Refração Ocular/fisiologia , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia
6.
PLoS One ; 17(2): e0263528, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35113959

RESUMO

PURPOSE: To evaluate predictors for success in corneal crosslinking (CXL) for keratoconus in a large cohort and extended follow-up. DESIGN: A retrospective study based on a prospectively built database. METHODS: Participants underwent CXL for keratoconus from 2007 to 2018. Statistical analysis was performed for patients with at least 1-year follow-up. We analyzed effects of CXL type (Epithelium-on or Epithelium-off and Accelerated (9mW/cm2@10min) or Standard (3mW/cm2@30min)) and pre-operative factors including age, gender, baseline LogMAR visual acuity (LogMARpre), maximal corneal power (Kmaxpre), pachymetry, refractive and topographic cylinders, spherical equivalent (SEpre), mean corneal power (MeanK) and follow-up time on outcome measures. The outcome measures were the final change of Kmax (Delta Kmax) and the final change in LogMAR visual acuity (Delta LogMAR). A more negative Delta Kmax or Delta LogMAR represents a favorable effect of crosslinking. RESULTS: 517 eyes had Kmax results, and 385 eyes had LogMAR results with more than one year follow-up. These eyes were included in the study. The mean follow-up time was 2.29 years. Mean Kmax decreased from 54.07±5.99 diopters to 52.84±5.66 diopters (p<0.001), and Mean LogMAR decreased from 0.28±0.20 to 0.25±0.21 (p<0.001). Non-accelerated epithelium-off CXL resulted in greater flattening of Kmax when compared with other protocols. Visual acuity improvement was similar when comparing different CXL protocols. Multivariate analysis showed four factors associated with negative Delta Kmax: high Kmaxpre, high SEpre, high MeanKpre, and non-accelerated procedure. Multivariate analysis showed three factors associated with negative Delta LogMAR: high LogMARpre, high SEpre, and Low MeanKpre. After excluding corneas with Kmaxpre >65 D or Pachymetry<400 microns, multivariate analysis showed that high Kmaxpre, high SEpre, and non-accelerated CXL were associated with negative Delta Kmax while high LogMARpre and high SEpre were associated with negative Delta LogMAR. CONCLUSION: CXL for keratoconus is a highly effective treatment, as evident by its effects on the outcome measures: Delta Kmax and Delta LogMAR. CXL was more successful in eyes with high Kmaxpre, high SEpre, and high LogMARpre, which express disease severity. The non-accelerated epithelium-off protocol was associated with greater flattening of corneal curvature but did not show a better effect on visual acuity as compared to the other CXL protocols.


Assuntos
Córnea/fisiopatologia , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/fisiopatologia , Adolescente , Adulto , Idoso , Paquimetria Corneana , Topografia da Córnea/métodos , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Refração Ocular , Estudos Retrospectivos , Riboflavina/uso terapêutico , Adulto Jovem
7.
PLoS One ; 17(2): e0263506, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35134078

RESUMO

Aspherical- and multi-curve rigid gas-permeable hard contact lenses (HCLs) have a flattened curve in the peripheral zone and are mostly used for patients with keratoconus who cannot wear glasses, soft contact lenses, or spherical HCLs. In this retrospective study, a total of 95 eyes of 77 patients who used aspherical- or multi-curve HCLs (mean age: 40.0 ± 11.0 years) were evaluated. This study examined the types of aspherical- and multi-curve HCLs, best-corrected visual acuity (BCVA) values before and after wearing HCLs, the association with the Amsler-Krumeich classification, duration of wear, corneal/conjunctival disorder, and the frequency of changing HCLs. There were 78 eyes that used aspherical-curve HCLs and 17 that used multi-curve HCLs. BCVA significantly improved from 0.42 logMAR to 0.06 logMAR after wearing either form of HCL. The Amsler-Krumeich classification showed that aspherical-curve HCLs were commonly used for patients with stage 2 keratoconus, and multi-curve HCLs were commonly used for stage 4 patients. The BCVA values were worse when the disease stage was more severe (stages 3 and 4) regardless of HCL type. The mean base curve of the lenses was steeper in multi-curve HCLs than in aspherical-curve HCLs. The more severe the disease stage, the steeper the base curve in both aspherical- and multi-curve HCLs. The duration of wear significantly improved from 2.1 h to 10.2 h, and corneal/conjunctival disorder similarly improved. The mean frequency of changing HCL types was 1.1 times. This study suggests that a flat peripheral curve design with aspherical- and multi-curve HCLs is useful for patients with keratoconus.


Assuntos
Lentes de Contato/tendências , Ceratocone/terapia , Adulto , Córnea/fisiologia , Topografia da Córnea/métodos , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acuidade Visual/fisiologia
8.
Exp Eye Res ; 216: 108959, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35074345

RESUMO

Kynurenine aminotransferases (KAT) are enzymes catalyzing formation of kynurenic acid (KYNA) from kynurenine. KYNA is a Janus-faced molecule of high biological activity. On the one hand KYNA was identified as a UV filter and neuroprotectant with free radical scavenging properties, but on the other hand it may contribute to photodamage of lens proteins resulting in cataract formation. Fuchs endothelial corneal dystrophy (FECD) and keratoconus (KC) are common, vision threatening corneal dystrophies whose etiology is not fully understood. In our previous works, we confirmed the presence of KATs in the human cornea together with GPR35, a receptor for KYNA. This prompted us to investigate the potential changes in the expression of three isoforms: KAT I, KAT II, and KAT III in normal and FECD- and KC-affected corneas. Immunohistochemistry accompanied by gene expression data mining revealed that the levels of neither KAT I, KAT II, nor KAT III are affected in FECD and KC. This constitutes evidence against the involvement of KATs in the pathophysiology of FECD and KC.


Assuntos
Distrofia Endotelial de Fuchs/fisiopatologia , Ceratocone/fisiopatologia , Transaminases/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Distrofia Endotelial de Fuchs/enzimologia , Perfilação da Expressão Gênica , Humanos , Imuno-Histoquímica , Ceratocone/enzimologia , Masculino , Pessoa de Meia-Idade , Receptores Acoplados a Proteínas G/metabolismo , Transaminases/genética
9.
Exp Eye Res ; 214: 108839, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34785203

RESUMO

PURPOSE: To explore the effect of age on corneal biomechanical properties following corneal cross-linking (CXL). METHODS: A total of 12 pairs of human eye-banked corneas (24 corneas, from 14 females and 10 males) were used in the study. The mean donor age was 48.5 years (ranging from 26 to 71 years). Corneas were divided into three age groups: A (26-41 years), B (42-57 years) and C (58-71 years), with four pairs in each group. For each pair, the right corneas were cross-linked using accelerated CXL with UVA (10 mW/cm2) and riboflavin, while the left corneas served as controls and were not exposed to either UVA irradiation or riboflavin. The corneal elastic modulus of the anterior, mid and posterior corneal stroma was measured using nanoindentation. RESULTS: The difference in the corneal elastic modulus following CXL was significant in the anterior (p = 0.00002) and mid stroma (p = 0.001); however, the difference was not significant in the posterior stroma (p = 0.27) when compared to control corneas. The corneal elastic modulus of the anterior stroma increased by 178.44% in Group A, 119.7% in Group B and 50.73% in Group C compared to control corneas. For the mid stroma, the elastic modulus increased by 47.35% in Group A, 25% in Group B and 24.56% in Group C. No differences were observed in the posterior stroma between age groups. CONCLUSIONS: Corneal elasticity showed a greater response to CXL in the younger group compared to older groups. CXL treatment showed effectiveness in enhancing stromal strength, and the effect was concentrated in the anterior and mid stroma with minimal impact on the posterior stroma in all age groups.


Assuntos
Envelhecimento/fisiologia , Colágeno/metabolismo , Córnea/fisiologia , Reagentes de Ligações Cruzadas/farmacologia , Módulo de Elasticidade/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Feminino , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Raios Ultravioleta
10.
Cornea ; 41(4): 462-469, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34743098

RESUMO

PURPOSE: The aim of this study was to compare the 4-year clinical outcomes of transepithelial diluted alcohol and iontophoresis-assisted corneal crosslinking (DAI-CXL) and standard corneal crosslinking (S-CXL) in adults with progressive keratoconus. METHODS: This retrospective study included 36 eyes of 36 keratoconic patients who underwent DAI-CXL (n = 18) or S-CXL (n = 18). Best spectacle-corrected visual acuity (BSCVA) and corneal topography parameters were analyzed at baseline and at 1, 2, 3, and 4 years of follow-up. Corneal demarcation line depth (DLD) at 1 month was measured, and the relation of DLD with corneal thickness (DL%) was assessed. RESULTS: BSCVA improved significantly only in S-CXL (P = 0.01). A significant decrease in maximum keratometry and mean keratometry occurred at 4 years in both groups (all P < 0.05), and these changes were similar in both groups (all P > 0.05). There was a significant reduction in the thinnest corneal thickness in S-CXL (P = 0.01); however, the mean thinnest corneal thickness in DAI-CXL remained stable (P = 0.094). Higher-order aberrations and coma aberration decreased significantly in both groups at 4 years (all P < 0.05), with a higher decrease in S-CXL (all P < 0.05). Spherical aberration showed a significant reduction only in S-CXL (P = 0.005). In contrast to the similar mean DLD in both groups, DL% in DAI-CXL was significantly greater than that in S-CXL (P = 0.032). There were no correlations between the improvement in BSCVA, maximum keratometry, mean keratometry, higher-order aberrations, and the mean DLD and DL% (all P > 0.05). CONCLUSIONS: DAI-CXL was as effective as S-CXL in arresting the progression of keratoconus and showed similar clinical results to S-CXL at the 4-year follow-up.


Assuntos
Reagentes de Ligações Cruzadas/uso terapêutico , Epitélio Corneano/efeitos dos fármacos , Etanol/administração & dosagem , Iontoforese/métodos , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Adulto , Colágeno/metabolismo , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Fotoquimioterapia/métodos , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
11.
Cornea ; 41(4): 408-416, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33859086

RESUMO

PURPOSE: The aim of this study was to assess the effect of corneal crosslinking on vision and keratometry in children and young adults with progressive keratoconus. METHODS: A retrospective medical records review of patients aged 22 years or younger with keratoconus who underwent corneal crosslinking between January 2013 and November 2019 at Byers Eye Institute at Stanford University was conducted. Outcome measures included logarithm of the Minimum Angle of Resolution corrected distance visual acuity (CDVA); keratometry, including maximum keratometry (Kmax); pachymetry; and total wavefront aberration. Measurements were taken at baseline and at 12 and 24 months postoperatively. RESULTS: Fifty-seven eyes of 49 patients aged 12 to 22 years were assessed. The mean preoperative CDVA was logarithm of the Minimum Angle of Resolution 0.38 ± 0.32 (20/48), with a mean postoperative CDVA of 0.29 ± 0.31 (20/39) and 0.31 ± 0.31 (20/41) at 12 and 24 months postoperatively, respectively. Compared with preoperative mean Kmax, there was an improvement of -0.8 diopters (D) to a mean postoperative Kmax of 59.1 ± 9.1 D at 12 months and -1.3 D to 59.7 ± 8.8 D at 24 months. Subanalysis excluding the second eye of patients who underwent bilateral crosslinking showed similar results. Linear mixed modeling showed significant improvement in Kmax at both 12 and 24 months postoperatively. Minimum central corneal thickness initially decreased but stabilized at 24 months after crosslinking. Total wavefront aberration remained stable. CONCLUSIONS: Corneal crosslinking stabilizes, and in some cases improves, visual and corneal parameters in pediatric and young adult patients with keratoconus. The procedure is safe and well-tolerated and may prevent keratoconus progression in young patients.


Assuntos
Colágeno/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Adolescente , Criança , Paquimetria Corneana , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
12.
Cornea ; 41(2): 165-170, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33859089

RESUMO

PURPOSE: To report the front corneal versus central and paracentral corneal changes after Bowman layer transplantation for keratoconus in a tertiary hospital in the United Kingdom. METHODS: Five eyes of 5 patients receiving Bowman layer transplant for advanced keratoconus in Royal Gwent Hospital (Newport, United Kingdom) were included. Preoperative and postoperative visual acuity; Kmax; Kmean, and corneal cylinder in the front cornea, 4.5 mm central, and 6 mm central; and corneal thickness were analyzed. RESULTS: Corneal flattening and reduction in corneal astigmatism was observed, more marked in the central and paracentral zone, allowing for improvement in best-corrected visual acuity with the aid of visual correction in 4 eyes. CONCLUSIONS: These results support previous data reporting Bowman layer transplantation as a useful strategy in the treatment of advanced keratoconus and suggest greater attention may be focused on central or paracentral corneal changes.


Assuntos
Córnea/diagnóstico por imagem , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Transplante de Córnea/métodos , Ceratocone/cirurgia , Refração Ocular/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
13.
Cornea ; 41(2): 201-205, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34050066

RESUMO

PURPOSE: To compare surgical outcomes and intraoperative and postoperative complications of big-bubble deep anterior lamellar keratoplasty (DALK) in patients with and without a history of previous corneal collagen crosslinking (CXL) for keratoconus. METHODS: Patients with keratoconus who underwent DALK surgery with big-bubble technique between January 2013 and January 2018 were retrospectively reviewed. Operative findings, intraoperative and postoperative complications, and visual and refractive outcomes were recorded. Patients were divided into 2 groups: with previous CXL (CXL-DALK group: 27 eyes) and without previous CXL (DALK group: 50 eyes). All parameters were compared between groups. RESULTS: Big bubble was successfully achieved in 24 eyes (88.9%) in the CXL-DALK group and in 45 eyes (90.0%) in the DALK group (P = 0.87). Type 1 bubble was obtained in 22 eyes (91.7%) in the CXL-DALK group and in 42 eyes (93.3%) in the DALK group (P = 0.79). Intraoperative microperforation occurred in 3 eyes (11.1%) in the CXL-DALK group and in 5 eyes (10.0%) in the DALK group (P = 1). Visual and refractive outcomes were similar between groups. The mean endothelial cell loss rates were 5.7% ± 2.3 at 1 year and 10.2 ± 3.1 at 2 years in the CXL-DALK group and 6.4% ± 4.7 at 1 year and 10.9% ± 5.4 at 2 years in the DALK group. Postoperatively, persistent epithelial defect was the most common complication in both groups, and postoperative complication rates were similar between groups. CONCLUSIONS: Our results have shown that previous CXL treatment does not influence the success of bubble formation and does not increase intraoperative or postoperative complication rates of DALK surgery for keratoconus. The improvement in visual acuity and refractive errors and endothelial cell loss rates were similar between CXL treated and untreated eyes after 2 years of follow-up.


Assuntos
Córnea/cirurgia , Topografia da Córnea/métodos , Seguimentos , Ceratocone/cirurgia , Ceratoplastia Penetrante/métodos , Complicações Pós-Operatórias/epidemiologia , Refração Ocular/fisiologia , Adolescente , Adulto , Córnea/patologia , Feminino , Humanos , Incidência , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Turquia/epidemiologia , Acuidade Visual , Adulto Jovem
14.
Acta Ophthalmol ; 100(1): e83-e90, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33750037

RESUMO

BACKGROUND: This study assesses the reliability of successive corneal biomechanical response measurements by the Corneal Visualization Scheimpflug Technology (CST, Corvis ST® , Oculus Optikgeräte, Wetzlar, Germany) in different keratoconus (KC) stages. METHODS: A total of 173 eyes (15 controls: 15 eyes, and 112 KC patients: stages 1|1-2|2|2-3|3|3-4|4, n = 26|16|36|18|31|26|5 according to Topographical KC Classification, TKC) were repeatedly examined five times with the CST, each after repositioning the patient's head and re-adjusting the device. Tomographical analysis (Pentacam HR® ; Oculus, Wetzlar, Germany) was performed once before and once after CST measurements. Outcome measures included (1) A1 velocity, (2) deformation amplitude (DA) ratio 2 mm, (3) integrated radius, (4) stiffness parameter A1 and (5) Ambrósio relational thickness to the horizontal profile (ARTh). The Corvis Biomechanical Index (CBI) is reported to be extracted out of these parameters. Mean values of the five measurements and Cronbach's α were calculated as a measure for reliability. RESULTS: Ambrósio relational thickness to the horizontal profile and SPA1 were significantly higher in controls (534|123) compared to TKC1 (384|88), TKC2 (232|66), TKC3 (152|55) and TKC4 (71|27; p < 0.0001). The other parameters were similar in controls and TKC1 (A1 velocity: 0.148|0.151 m/s; integrated radius: 8.2|8.6 mm-1 ), but significantly higher in TKC stages 2 to 4 (DA ratio 2 mm: 5.5|6.3|8.0; A1 velocity: 0.173|0.174|0.186 m/second; integrated radius: 10.9|12.8|19.0 mm-1 ; p < 0.0001). All parameters proved to be highly reliable (Cronbach's α ≥ 0.834) and the corneal tomography remained unaffected. CONCLUSIONS: The individual parameters included in the CBI (consisting of ARTh, SPA1, DA ratio 2 mm, A1 velocity and integrated radius) are highly reliable but differ KC stage-dependently.


Assuntos
Córnea/patologia , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Adulto , Córnea/fisiopatologia , Progressão da Doença , Elasticidade , Feminino , Seguimentos , Humanos , Ceratocone/fisiopatologia , Masculino , Curva ROC
15.
Cornea ; 41(1): 16-22, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33630812

RESUMO

PURPOSE: To investigate the epidemiologic, demographic, and basic clinical characteristics of individuals with keratoconus managed by optometrists in New Zealand (NZ)/Aotearoa. METHODS: A prospective, longitudinal, nationwide, survey protocol was completed for every patient with keratoconus who underwent a consultation with participating optometrists in a 2-year period. Data for each patient included date of birth, sex, self-reported ethnicity, new or previous diagnosis, uncorrected (UCVA) and best-corrected visual acuity (BCVA), type of refractive correction required to obtain BCVA and keratometric readings obtained using keratometry or computerized topography. RESULTS: One thousand eight hundred sixty-nine cases were identified, with a mean age of 41.0 ± 15.7 years, 56.4% being men, and 87.3% with previous diagnosis. The distribution of cases was skewed toward Auckland (41.6%), Waikato (21.3%), Wellington (16.8%), and Bay of Plenty (13.3%). Self-reported ethnicities were predominantly NZ European (54.4%), Maori (24.7%), and Pacific Peoples (15.5%), disproportionate to the general population profile (74.0%, 14.9%, and 7.4% respectively). Most eyes (64.3%) were managed with rigid contact lenses (corneal lens in 34.2%). The mean K-mean was 49.0 ± 5.7 D. The mean UCVA was 6/42 and BCVA was 6/9. Maori and Pacific Peoples had both the highest K-mean and proportions of eyes graded stage IV on the Amsler-Krumeich scale. CONCLUSIONS: The results indicate that keratoconus is relatively common in NZ with at least 1869 patients managed by optometrists in 2 years. Most eyes had mild to moderate disease; however, Maori and Pacific Peoples seem to have greater disease severity. An ethnic predilection is apparent, with Maori and Pacific Peoples overrepresented relative to their population proportions, reinforcing a long-held clinical suspicion.


Assuntos
Substância Própria/patologia , Topografia da Córnea/métodos , Ceratocone/epidemiologia , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Feminino , Seguimentos , Humanos , Incidência , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Nova Zelândia/epidemiologia , Estudos Prospectivos
16.
Cornea ; 41(4): 435-442, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267059

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population. METHODS: This study was conducted on 95 contact lens-intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method. RESULTS: The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 ± 0.39 to 0.38 ± 0.22 (P < 0 0.001) and 0.33 ± 0.21 to 0.13 ± 0.11 logMAR (P < 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from -2.52 ± 2.62 to -0.76 ± 1.78 D (P < 0.001) and -4.14 ± 1.64 to -1.91 ± 1.18 D (P < 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (P< 0.001). Primary coma and spherical aberration values showed a significant increase (both, P < 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1). CONCLUSIONS: AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus.


Assuntos
Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Aberrometria , Adulto , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Irã (Geográfico) , Ceratocone/fisiopatologia , Masculino , Desenho de Prótese , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia
17.
Exp Eye Res ; 213: 108804, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34756941

RESUMO

PURPOSE: Alike keratoconus (KC), keratoglobus (KG) and pellucid marginal degeneration (PMD) belong to ectatic corneal diseases. While there are numerous studies on keratoconus pathophysiology, there is no exact knowledge on genetic and pathophysiological background of KG and PMD, so far. It is not yet clarified, whether KG and PMD are independent clinical entities or represent different stages of the same disease. Our purpose was to investigate key parameters concerning collagen synthesis, intracellular LOX expression and inflammation in corneal stromal cells of KG and PMD subjects, in vitro. METHODS: Normal human keratocytes of corneas from the LIONS Cornea Bank Saar-Lor-Lux, Trier/Westpfalz and human keratocytes of KG and PMD patients were isolated and cultured as keratocytes. To examine Collagen I and V (Col I, Col V), heat shock protein 47 (Hsp47), Lysyl Oxidase (LOX), nuclear factor kappa B (NF-κB) mRNA and protein expression in all cell types, quantitative PCR and Western blot analysis has been performed. RESULTS: Col5A1 mRNA expression was significantly lower in KG and PMD keratocytes and LOX mRNA expression was significantly higher in KG-keratocytes, compared to controls. Col1A1, Hsp47 and NF-κB mRNA expression and the analyzed protein expressions did not differ from controls, in KG or PMD. CONCLUSIONS: Col5A1 mRNA expression is decreased in KG and PMD and LOX mRNA expression is increased in KG. Therefore, the pathophysiology of KG and PMD differs from KC and these seem to be from KC independent entities. The explanation of the peripheral corneal thinning in KG and PMD must be investigated in further studies.


Assuntos
Colágeno Tipo V/genética , Distrofias Hereditárias da Córnea/genética , Ceratócitos da Córnea/metabolismo , Regulação da Expressão Gênica/fisiologia , Ceratocone/genética , Proteína-Lisina 6-Oxidase/genética , RNA Mensageiro/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Western Blotting , Células Cultivadas , Distrofias Hereditárias da Córnea/metabolismo , Distrofias Hereditárias da Córnea/fisiopatologia , Distrofias Hereditárias da Córnea/cirurgia , Substância Própria/citologia , Feminino , Voluntários Saudáveis , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Ceratocone/cirurgia , Ceratoplastia Penetrante , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase em Tempo Real , Doadores de Tecidos
18.
Sci Rep ; 11(1): 21079, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702891

RESUMO

Numerous approaches have been designated to document progression in keratoconus, nevertheless there is no consistent or clear definition of ectasia progression. In this present study, we aim to evaluate Keratoconus Enlargement (KCE) as a parameter to document ectasia progression. We define KCE as an increase of more than 1D in the anterior curvature of non-apical corneal areas. We have designed a longitudinal study in 113 keratoconic eyes to assess keratoconus progression. KCE was compared with variables commonly used for detection of keratoconus progression like Kmax, Km, K2, PachyMin, D-Index, Corneal Astigmatism and PRC of 3.0 mm centered on the thinnest point. The variations of keratometric readings, D-index and ELEBmax showed positive associations with KCE. Evaluating the performance of Kmax, D-index and KCE as isolated parameters to document keratoconus progression we found a sensitivity of 49%, 82% and 77% and a specificity of 100%, 95% and 66% to detect keratoconus progression (p < 0.001 for all). This difference in sensitivity can be explained by the changes in keratoconus outside the small area represented by Kmax. The inclusion of KCE should be considered in the evaluation of keratoconus progression in conjunction with other variables to increase the reliability of our clinical evaluation.


Assuntos
Astigmatismo , Córnea , Topografia da Córnea , Progressão da Doença , Acuidade Visual , Adolescente , Adulto , Astigmatismo/diagnóstico por imagem , Astigmatismo/fisiopatologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico por imagem , Ceratocone/fisiopatologia , Estudos Longitudinais , Masculino
19.
Sci Rep ; 11(1): 12971, 2021 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-34155283

RESUMO

This study analyzes the relationship between contrast-sensitivity and higher-order aberrations (HOA) in mild and subclinical-keratoconus in subjects with good visual-acuity (VA). Keratoconus group (including subclinical-keratoconus) and controls underwent autokeratometry, corneal-tomography, autorefraction and HOA measurement. Contrast-sensitivity was tested using a psychophysical two-alternative forced-choice Gabor patches in three blocks (6, 9, 12 cycles/deg). Controls were compared to the keratoconus group and to a keratoconus subgroup with VA of 0.00 LogMar group ("keratoconus-0.00VA"). Spearman correlation tested association between HOA and contrast-sensitivity. Twenty-two keratoconus subjects (38 eyes: 28 keratoconus, 10 subclinical-keratoconus, 20 keratoconus-0.00VA) and 35 controls were included. There was a significant difference between control and keratoconus, and between control and keratoconus-0.00VA, for keratometry, cylinder, thinnest and central corneal thickness (p < 0.001). Controls showed lower HOA and higher contrast-sensitivity for all spatial-frequencies (p < 0.001). Most HOA were negatively correlated with contrast-sensitivity for all spatial-frequencies for keratoconus group and for 9 and 12 cycles/deg for keratoconus-0.00VA. Keratoconus subjects with good VA showed reduction in contrast-sensitivity and increased HOAs compared to controls. HOA and contrast-sensitivity are inversely correlated in subjects with mild keratoconus despite good VA. This suggests that the main mechanism underlying the decreased vision quality in keratoconus is the increase of HOA.


Assuntos
Sensibilidades de Contraste , Aberrações de Frente de Onda da Córnea , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Refração Ocular , Acuidade Visual , Adulto Jovem
20.
J Ayub Med Coll Abbottabad ; 33(2): 175-178, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34137523

RESUMO

BACKGROUND: Keratoconus is a progressive, noninflammatory, bilateral ectatic corneal disease, characterized by paraxial stromal thinning and weakening that leads to corneal surface distortion. The objective of this research was to determine the effectiveness and safety of collagen crosslinking in progressive keratoconus, with keratometry (Kmax) value of 50 diopters or above. It was a retrospective study, conducted at Bodla Eye Care (BEC) and Multan Medical and Dental College, Multan (MMDC) from May 2018 to November 2019. METHODS: In this research 52 eyes were studied. The best-corrected visual acuity, uncorrected visual acuity, maximum keratometry, mean keratometry value, and thinnest corneal thickness before surgery and 12 months after Cross-linking were observed. A Galeili G6 by Zeimer ophthalmic system was used to measure the clinical parameters. Dresden protocol was followed in this study. A written ethical approval was obtained and research was conducted under the light of declaration of Helsinki. RESULTS: The average logarithm of the minimum angle of resolution (logMAR) of the uncorrected visual acuity decreased from 0.66±0.41 D to 0.49±0.40 D (p=0.012), while the mean thinnest point thickness of the cornea decreased from 435.31 37.91 µm to 419.41±70.12 µm (p=0.004) after 12 months. The decreases in the mean logMAR of the BCVA, Kmax and Kmean values were not analytically important (p>0.05) at the 12-month follow-up 94.2% positive results were obtained. CONCLUSION: Collagen cross-linking treatment was safe and maintained both the visual acuity and tomographic parameters at the one-year follow-up in eyes.


Assuntos
Colágeno/metabolismo , Córnea/metabolismo , Ceratocone/metabolismo , Adolescente , Adulto , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Humanos , Ceratocone/fisiopatologia , Masculino , Procedimentos Cirúrgicos Oftalmológicos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Tomografia Computadorizada por Raios X , Raios Ultravioleta , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...